China Manufacturers Directory
  Inquiry Basket Inquiry Basket (0) | Sign In |

Home » Offer List » Switching power supply with CE » Dual Output Switching Power Supply

Offer Details

Add to Basket Dual Output Switching Power Supply

Offer Type:
Offer Group: Switching power supply with CE
Offer Post Time: 2009-11-07
Expiration Date: 2010-05-26
Details: Low price and high reliability
105 degrees output capacitor
AC input power suitable for the world
Hight efficiency and low operation temperature
Soft-start current can reduce the AC input impact effecticly
With Short-circuit and owwerload protection
Compact size, light weight
100% full-load burning test
Installed with EMI filter, minimum wave
  Model
Specification
D-30AD-30B
CH1CH2CH1CH2
DC output voltage5V12V5V24V
Output voltage error(Note:2)±2%
 
+3,-7%±2%+3,-5%
Rated output current4A
 
1A2.2A1A
Output current rage0.5-4A
 
0.1-1A0.5-4A0.1-1A
Wave and noise(Note :3)50mVp-p100mVp-p50mVp-p100mVp-p
Inlet stability(Note :4)±0.5%±1%±0.5%±0.5%
Load stablity (Note :5)±0.5%±4%±0.5%±0.5%
DC output power32W35W
Efficiency72%74%
Adjustable range for DC voltageCH1:+10,-5%CH1:+10,-5%
AC input voltage range85-132VAC/170-264VACSelected by switch47-63Hz;240-370VDC
Input current0.8A/115V 36A/230A
AC INnrush currentCold-start current30A/115V 60A/230V
 
Leakage current<0.5mA/240VAC
Overload proctection105%-150%Type:Foldback:current limiting reset:auto recovery
Over-voltage protection…………
High-temperature protection…………
Temperature coefficient±0.03%/ºC(0-50ºC)
Setup rise hold up time200ms,50ms,30ms
Vibration10-500Hz,2G 10min,/1cycle,Period for60min,Each axes
Withstand voltageInput and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC
Isolation resistanceInput and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ
Working temperature and humidity-10ºC~+60ºC(Refer to output derating curve),20%~90%RH
Store temperature and humidity-20ºC~+85ºC,10%~95%RH
Overall dimension129×98×38mm
Weight0.4Kgs
Safety standardsMeet UL 1012 requirement (Not apply for the mark)
EMC standardsMeet FCC Part15 J Conduction class A
Note:
1.The testing condition for the paramenter above is :230VAC input,rated load,25ºC70% RH.Humidity.
2.Error.include the setting error,line stability and load stability.(Note:5).
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.
5.Load stability test:the load is from 0% to 100%.
6.Total output canbe maximum Current,total load can not exceed the maximum output power.
Click here to send inquiry
 
"My Showroom" service is provided by Made-in-China.com
Made-in-China.com provides Product Catalog , Manufacturers / Suppliers , Quick Offers & Trade Offers
Related Searches:Power Supply, Switching Power Supply, AC Adapter Power Supply, DC Power Supply, Power Switch, DC Power Supply Circuit, Power Supply trade, Switching Power Supply trade, DC Power Supply trade
Made-in-China.com - The world of "Made in China" online!